《环境工程学报》第三届编委会2019年度工作会议顺利召开    《环境工程学报》获“2017年度科学传播特殊贡献单位”荣誉称号    《环境工程学报》启用DOI通知设为首页|加入收藏
引用本文
  • 万琼,雷茹.生物生态耦合系统对分散式农村生活污水的深度净化[J].环境工程学报,2019,13(7):1602-1611.DOI:10.12030/j.cjee.201810027    [点击复制]
  • WAN Qiong,LEI Ru.Deep purification of decentralized rural domestic sewage by vertical coupled biological and ecological system[J].,2019,13(7):1602-1611.DOI:10.12030/j.cjee.201810027   [点击复制]
【打印本页】 【在线阅读全文】【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 49次   下载 43 本文二维码信息
码上扫一扫!
生物生态耦合系统对分散式农村生活污水的深度净化
万琼1,雷茹1
0
(1.西安科技大学建筑与土木工程学院,西安 710054;2.上海交通大学环境科学与工程学院,上海 200240)
摘要:
针对分散式农村生活污水排放标准的提升,通过集约式立体生物生态耦合系统对农村生活污水二级处理出水进行深度净化,采用国家标准方法对系统进出水中的COD、氨氮、TN和TP进行了测定,评价了系统对各污染物质的去除效果。结果表明:在实验进水COD,氨氮,TN和TP均属于《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级B标准时,系统稳定后实验出水的COD,氨氮,TN和TP的浓度分别可降至9~35、1~7、8.0~14.9、0.20~0.47 mg·L-1,均满足一级A 标准。随着流水分区不同,COD,氨氮,TN和TP的浓度逐渐降低。采用集约式立体生物生态耦合系统可使农村生活污水二级处理出水水质达到一级A排放标准,实现深度净化的需求。
关键词:  生物生态组合技术  农村生活污水  深度处理
DOI:10.12030/j.cjee.201810027
投稿时间:2018-10-09
基金项目:国家重点基础研究发展计划项目2016YFC0400805国家重点基础研究发展计划项目(2016YFC0400805)
Deep purification of decentralized rural domestic sewage by vertical coupled biological and ecological system
WAN Qiong1,LEI Ru1
(1.School of Architecture and Civil Engineering, Xi'an University of Science and Technology, Xi'an 710054, China;2.School of Environmental Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China)
Abstract:
Aiming at the improvement of the water quality standard of decentralized rural-domestic sewage secondary effluent, the intensive vertical coupled biological and ecological technology was used to deeply purify the secondary effluent of rural domestic sewage. The COD, ammonia nitrogen, TN and TP in the influent and effluent were measured according to the national standard method, and the removal efficiencies of various pollutants by this coupled system were evaluated. Experimental results show that when the influent water quality parameters, such as COD, ammonia nitrogen, TN, and TP, conformed to town sewage treatment plant pollutant discharge standard (GB 18918-2002) in the level I class B standard, the stable effluent concentrations of COD, ammonia nitrogen, TN, and TP could be reduced to 9~35, 1~7, 8.0~14.9 and 0.20~0.47 mg·L-1, respectively, which could meet the level I class A standard. The concentrations of COD, ammonia nitrogen, TN and TP are gradually decreased at different zones along the water flow direction. The vertical coupled biological and ecological technology can meet the requirements of deep purification for secondary treatment effluent of rural domestic sewage and achieve the level I class A standard. This study provides a theoretical reference for the popularization and application of the technology.
Key words:  vertical coupled biological and ecological technology  rural domestic sewage  advanced treatment